PWF Runner Flowmeter

          The PWF series  flow sensor adopts a radial rotary structure and collects the rotary speed through Hall effect to obtain parameters such as flow velocity and flow rate.
    Due to the mechanical structure of the impeller, this impeller flow sensor is not suitable for measuring fluids containing large solid particles, fibers, and high viscosity The overcurrent section is made of corrosion-resistant materials, which can be used in harsh corrosive environments;

          The five bladed impeller ensures excellent dynamic balance characteristics, greatly improving the linear accuracy and repeatability accuracy of the sensor. The plug-in installation structure allows this sensor to be quickly installed to DN15-DN600.On various material pipelines. In addition, the sensor adopts NPN collector output and high-speed pulse output, which can directly transmit pulse signals to any related flow transmitter or PLC. It has standard microwave signals and anti-interference ability.The maximum output distance that can be helped is 300 meters.


    PWF flow Sensor:

    Size: DN15-DN150 (MaxDN300)
    Measurement: 0.15 - 10 m/s
    Output signal: square wave, NPN;
    Working voltage: 5-24 VDC
    Material and Process:
    Body Material: UPVC PPH PVDF SS316L
    Wheel material: PPCF/PPH/PVDF
    Sealing Oring: FPM/EPDM
    Cable : 5 m (customizable)
    Protection level: IP65 (quick plug type)
    IP68 (cable integrated) working temperature and pressure:
    UPVC: 12.5bar@25  ℃ -2.5bar@50 ℃
    PPH:  10bar@25  ℃ -  1.7bar@80  ℃)
    PVDF:  12.5bar@25  ℃ -  2.5bar@100  ℃

    316L:  30bar@100  ℃)


    MNT02.01 Flowmeter Monitor
    The MNT02.01 series display transmitter is a single channel digital display instrument - PWF flow transmitter, which can be connected to the pulse signal of a rotary flowmeter and has the characteristics of high-precision measurement and fast response,
    At the same time, MNT02.1 provides one set of analog signals, two sets of SSR relays, and one set of MODBUS RS485 output terminals for easy connection with backend electrical control equipment .
    MNT02.01 Collecting PWF
    The pulse signal of the rotary flowmeter is equipped with multi-point calibration/online calibration, which can provide users with convenient use and online debugging functions, as well as professional signal transmission functions.
    Display content: instantaneous flow and cumulative flow
    Unit: (m3/h,L/h,m3,L )
    Shell material: ABS+PC
    Specification size: 100mm × 100mm (dial), opening size: (92mm × 92mm)
    Display window: 3.5 " TFT
    Response frequency: 1"
    Language: Chinese/English
    Fixed method: panel installation, wall mounted installation) Working temperature:- 20 ~ 60 ℃)
    Working humidity: 0-90% (non condensing)
    Protection level: IP65 screen display front-end)
    Working Valtage: 24VDC
    Input signal: PWF NPN
    Output signal: 4-20mA × 1; SSR ×2; MODBUS RS485 ×1
    Application:
    Process control in water treatment, chemical, metallurgical, pharmaceutical and other industries


    File Name : Format: Size: Download:

Related products

EFFAST LOGO-png 2756x772.png

  • +86 755-85207392

  • +86 755-28393447

  • sales@effast.cn